produits

services

événements

boutique

contact


Siège international
2300 Riverchase Center
Birmingham, AL 35244
USA

tél. : 888.246.8338
tél. : 205.967.7880
fax : 205.870.0304

BioHorizons Canada
21 Amber Street, Unit #6
Markham, Ontario L3R 4Z3
Canada

tél. : 866.468.8338
fax : 905.944.1894

BioHorizons Chile, S.A.
Av. Manquehue Norte 1337 Office 31
Vitacura
Santiago
Chile

tél. : +56 (2) 23619519
fax : +56 (2) 361.9521

BioHorizons Italia Srl
Via Ettore Cristoni, 88
40033 Casalecchio di Reno (BO) Italie

numero verde +800.063.040
tél. : +39.051.59.07.00
fax : +39.051.57.61.06

Bureau espagnol
BioHorizons Spain
Calle Oruro, 9
28016 Madrid,
Espagne

tél. : +34.91.713.10.84
fax : +34.91.355.83.75

BioHorizons UK
Richmond House
Oldbury Road
Bracknell
Berkshire RG12 8TQ
Royaume-Uni

tél. : +44 (0)1344 752560
fax : +44 (0)1344 868049

Implants dentaires Single-Stage

Implants dentaires Single-Stage

Implants dentaires Single-Stage

Implants dentaires Single-Stage

Contrairement aux modèles d'implants incorporés au niveau des tissus mous, les implants dentaires Single-Stage sont dotés de la technologie Power Thread de BioHorizons, dont la superficie maximale permet de contrer les forces occlusives élevées souvent constatées dans la zone postérieure. Pour les dentistes, c'est l'assurance que la position de l'implant restera stable sur le long terme, même avec une hauteur de crêtes limitée ou une dureté osseuse moindre.

Implants dentaires Single-Stage

specifications2

type de corps
  • parois parallèles
connexion
  • hexagone interne
  • conical connection
placement
  • niveau du tissu
traitement de surface
  • Laser-Lok collar
  • Corps RBT
présentation
  • sans pilier
diamètres plateforme
  • 3,5 mm
  • 4,5 mm
  • 5,7 mm
diamètres du corps
  • 3,5 mm
  • 4,0 mm
  • 5,0 mm
  • 6,0 mm
longueurs
  • 7mm
  • 9mm
  • 10,5 mm
  • 12mm
  • 15mm

Laser-Lok: better science, better implants

Control cellular migration - control esthetic outcomes

Only the Laser-Lok surface has been shown using light microscopy, polarized light microscopy and scanning electron microscopy to also be effective for soft tissue attachment. 3,4

"There is no other implant that shows functional orientation of fibers. There is not one. This is the only one. This is so important." 5

— Dr. Edward P Allen

Laser-Lok vs standard implant

informations supplémentaires

  1. Functional Surface Area: Thread-Form Parameter Optimization for Implant Body Design. J.Todd Strong, Carl E. Misch, DDS, MDS, Martha W. Bidez, PhD, Prasad Nalluri. Compendium / édition spéciale. vol. 19, n° 3, 1998.
  2. Implants are not available in all platform diameter, body diameter and length configurations. Please visit store.biohorizons.com for full availability.
  3. Preuves histologiques de fixation d'un tissu conjonctif sur un implant dentaire humain.
    M Nevins, ML Nevins, M Camelo, JL Boyesen, DM Kim.
    International Journal of Periodontics & Restorative Dentistry. vol. 28, n° 2, 2008.
  4. Histologic evidence of a connective tissue attachment to laser microgrooved abutments: a canine study.
    M Nevins, DDS, DM Kim, DDS, DMSc, SH Jun, DDS, MS, K Guze, DMD, P Schupbach, PhD, ML Nevins, DMD, MMSc.
    Accepted for publication: IJPRD, Vol 30, No. 3, 2010.
  5. Symposium 2013 Laser-Lok highlights
    Available at: Laser-Lok highlights
Non disponible dans tous les pays.